The H250FDN is the 250,000 BTU natural gas model in Hayward's Universal H-Series low NOx heaters. Hayward sizes it for pools up to about 750 sq ft of surface area, and it heats a 400 gallon spa 30 degrees F in about 29 minutes.
It has a cupro-nickel heat exchanger, forced draft combustion with hot surface ignition, and 2 in. x 2-1/2 in. water connections. It runs on 120V or 240V.
This model burns natural gas only. The newer version of this heater with OmniX built in is the HS250FDN.
Highlights
Cupro-nickel heat exchangerStandard. Hayward uses it to resist corrosion from unbalanced water chemistry.
Low NOxMeets clean air quality standards.
Built-in bypassHandles pump flow up to 125 GPM without an external bypass.
Forced draft combustionA blower moves air through the burner, with a silicon nitride hot surface igniter.
Specs
Gas input250,000 BTU/hr
FuelNatural Gas
Thermal efficiency84%
Minimum water flow25 GPM
Maximum water flow125 GPM
Water connections2 in. x 2-1/2 in.
Gas connection at heater3/4 in.
Gas inlet pressure4.5 to 10.5 in. w.c.
Electrical120 or 240VAC, 60 Hz, single phase, 5.5 A maximum
Circuit protection15 A recommended
IgnitionSilicon nitride hot surface igniter, forced draft combustion
Heat exchangerCupro-nickel
Cabinet size25 in. wide x 29-1/2 in. deep x 24 in. high
Indoor vent pipe4 in. diameter (natural gas)
EmissionsLow NOx
CertificationCSA
Warranty and installation
WarrantyHayward warranty: 3 years parts, 1 year labor. Claims go to Hayward.
InstallationProfessional installation available in LA and Ventura County
Questions
What size pool is the H250FDN for?Hayward's sizing chart puts this model at pools up to about 750 sq ft of surface area, based on a 30 degree F temperature rise, 3.5 mph average wind and elevation up to 2,000 ft. For an indoor pool, divide the surface area by 3 before picking a size.
How fast does it heat a spa?Hayward lists the time to raise spa water 30 degrees F: 200 gallons in about 15 minutes, 300 gallons in about 22 minutes, 400 gallons in about 29 minutes, 500 gallons in about 36 minutes. That is for an insulated, covered spa; heat lost to the spa walls adds to it.
Can I run it on propane?No. This is the natural gas model.
What pump flow does it need?At least 25 GPM through the heater, and no more than 125 GPM. The heater has a built-in bypass.
Is there a version with phone control?Yes. The HS250FDN is the same size heater with OmniX built in.
We'll email you back, usually the same business day. Or call (818) 818-6559 (Mon–Fri 8–5, Sat 8–4).
You are chatting with an AI assistant, not a person. It can be wrong: please double-check part numbers against your equipment label. By using this chat you agree that it is recorded and saved, that it is processed by our service providers, and that our team may read it or join. See our Privacy Policy. Need a person? or call (818) 818-6559.